SPECS :
Applications:
- Airport & Public Facility Security and Safety
- Loss Prevention
- Restrict the egress of wandering patients for safety
- Restrict the egress of commercial center patrons for security
Certifications:
- ANSI/BHMA A156.3-2014 Grade 1
- UL305 Listed for Panic Hardware
- UL/cUL Listed for up to 3 hours for “A” labeled doors
- UL10C Positive Pressure Rated
- UL10B Neutral Pressure Rated
- Complies with ANSI 117.1 for accessible buildings and facilities
Code Compliance:
- IFC International
- IBC International Building Code
- NFPA 101 Life Safety Code
- NFPA 1 Uniform Fire Code
- California Building Code
Cover: Stainless steel, zinc
Cover Tube: Aluminum
Cylinders Cores: Requires a 3902 mortise cylinder with standard cam, sold separately
Electrical Specifications:
- DE; 540mA @ 24VDC signal; 790mA @24VDC Tandem
- Reset/RX Input: N/O, Dry contact
- bypass Input: N/O, Dry contact
- DPS Input: N/O, Dry contact
Electricmodifications: OBDE – Onboard Delayed Egress
End Caps: Zinc
Fasteners:
- Wood and machine screws
- Thru-bolts
Notes:
- Rod covers by others recommended for SVR/LBR Applications
- Recommended to be used on appropriately reinforced doors
Operational Functionality:
- Typically used on exit doors when unauthorized egress is initiated when in the locked mode. The door unlocks after 15 seconds permitting egress
- SVR exits must include rod covers
- Door position switch (DPS) is recommended
Outputs:
- Secure / Unsecure status
- Egress initiation status
- Released / Bypass status
- Alarm Relay 1A @30VDC SPDT, Dry
- Door security relay 1A@30VDC SPDT, Dry
Product Description: Available for all 4500 series devices
Product Number: 4501 OBDE
Push Bar: OPTIONAL Photoluminescent push bar cover available
Trim:
- Escutcheon trim
- Pull plate trim
Reviews
There are no reviews yet.